Store energy. Every way.™

TECHNOTHERM Dynamo S 1000 – 1 kW electric radiator with heat storage and PV control

38 919 Kč incl. VAT

Wall-mounted 1 kW heat-retaining electric radiator with two separately controlled fireclay rows. The integrated Shelly interface can coordinate the storage row with photovoltaic surplus, dynamic prices or a compatible energy-management system.

In stock.

Request pricing, configuration, compatibility or project design

We will confirm compatibility, project scope, delivery, lead time and the system price.

Remove

Description

Heat-retaining electric radiator · two interlocked 1 kW circuits · PV and tariff control

Schedule room heat for solar surplus or lower-price electricity

TECHNOTHERM Dynamo S 1000 is a wall-mounted electric radiator with two separate rows of fireclay heat-storage elements. The front 1 kW circuit heats the room during the main period of use. The rear 1 kW circuit is a separately scheduled storage row that can be enabled when photovoltaic surplus or a favourable electricity-price signal is available. Electrical interlocking prevents the two rows from operating at the same time, so the active heater load remains 1 kW rather than 2 kW.

Dynamo S is a partial-storage radiator, not a heat pump and not a large night-storage heater. It does not multiply electrical energy. Its benefit is the ability to move part of the heating demand in time and to continue releasing retained heat after the active circuit switches off. The manufacturer gives up to approximately three hours of residual heat as a reference; actual duration depends on the charge level, room heat loss, airflow and temperature conditions.

Active input1 kW
Heating circuits2 × 1 kW, interlocked
Dimensions680 × 630 × 120 mm
Installation design loadup to 48 kg
ProtectionIP20 · Class I
Controlthermostat + Shelly interface

A room-heating row and a separately controlled storage row

The front heating row follows the room thermostat and maintains the selected temperature during the main operating period. The rear row can charge its fireclay elements during configured times. When the storage row is active, the controller blocks the front circuit. The warmed mineral mass then releases heat by radiation and natural convection after charging ends.

This arrangement is useful where the household or building can identify a genuine solar surplus or a favourable tariff window. The result still depends on the building heat loss and correct control settings. Charging the radiator at the wrong time can overheat the room and increase consumption, so the product should be sized from a heat-loss calculation and commissioned as part of the actual electrical and energy-management system.

Two physically separate rows

Normal room heating and scheduled storage use different circuits; the electrical interlock prevents simultaneous operation.

PV-surplus destination

A compatible energy-management system can enable the storage circuit through the integrated Shelly interface when surplus is available.

Dynamic-price scheduling

The storage row can be charged during selected lower-price hours instead of being left permanently active.

Residual heat

The fireclay mass smooths room heat delivery; the stated duration of up to about three hours is conditional, not guaranteed.

Weekly room control

Comfort+, comfort and setback temperatures, adaptive start and open-window detection support regular operation.

Compact wall depth

The 12 cm cabinet provides limited heat storage without the size and floor loading of a full storage heater.

Dynamo S 1000 specifications

The official TECHNOTHERM catalogue identifies the white Dynamo S 1000, order number 452610210, 1 kW output and 680 × 630 × 120 mm dimensions. It gives a product weight of approximately 43 kg. The current German installation manual MAG-000480, edition 07/26, gives 48 kg for the 1 kW model; use the more conservative 48 kg for wall, lifting and access planning.

Store SKU / manufacturer order number 452610210
Model and colour Dynamo S 1000, white
Heating circuits 2 separate rows; only one circuit can operate at a time
Input per active circuit 1,000 W
Supply 230 V, 1/N/PE, 50 Hz
Dimensions W × H × D 680 × 630 × 120 mm
Catalogue / installation-manual weight approximately 43 / 48 kg; plan the installation for 48 kg
Ingress protection / protection class IP20 / Class I
Mounting wall-mounted on two vertical U-rails with 500 mm spacing
Indicative room range approximately 5–12 m²; always verify by heat-loss calculation
Residual heat reference up to approximately 3 hours depending on operating conditions
Room control integrated thermostat, weekly programme, adaptive start and open-window detection
Energy-management interface integrated Shelly interface for the rear storage circuit

Room thermostat and surplus control are separate functions

The local thermostat manages room temperature and schedules. Remote TECHNOTHERM room control requires the appropriate SmartBox and app configuration. The Shelly interface is a separate route for enabling the rear storage circuit from a compatible energy-management system. An inverter, meter, SmartBox, EMS, third-party software and any subscription are not included unless expressly stated in the quotation.

WodaTherm™ checks the inverter, meter, local network, switching logic and protection concept before confirming automatic surplus operation. The presence of a Shelly interface alone does not prove direct compatibility with every inverter portal.

For smaller rooms with a verified heat requirement

Dynamo S 1000 can serve as main, supplementary or transitional electric room heating where the heat-loss calculation supports a 1 kW appliance and part of the demand can be shifted in time. It is intended for dry indoor rooms and is not selected from floor area alone. The indicative room range is only a planning aid.

Check the wall, clearances and supply circuit before installation

The manual requires at least 5 cm from the sides to masonry, 10 cm to combustible side materials, 8 cm above the floor, 10 cm below a non-combustible element, 15 cm below a combustible element and 50 cm clear in front. The control section remains on the right. The wall and fixings must safely carry the design load, and the heater must never be covered or installed directly below a socket.

Protective earthing and the supply circuit must comply with local rules. Any fixed electrical connection is work for a qualified person and must follow the current manual. In stock. WodaTherm™ confirms unloading, carrying access and delivery date with the order. Installation, SmartBox, metering, subscriptions and external energy-management components are included only when expressly quoted.

Current Dynamo installation and operating manual hosted by WodaTherm™

Download the Dynamo installation and operating manual

The documentation supplied with the actual appliance takes precedence for clearances, wall mounting, electrical connection, commissioning and safe use.

Additional information

Weight 48 kg
Dimensions 68 × 63 × 12 cm
0
0
Your Cart
Your cart is emptyReturn to Shop